Skip to main content
A practice preset is data that you copy into your project. It holds a paper style for each kind of drawing, the saved-view settings that go with it, and the viewport settings of a sheet. Floorkit does not register these presets and does not use them by default. A drawing without them looks as it did before. This page gives two examples, made from two real sets of UK permit drawings. The two practices draw differently: Epsom draws the site boundary as a red dashed line and fills new walls in tan, and Bexley draws the boundary as a black chain line and draws new timber walls as a stud zigzag. So there are two presets, not one UK default. The last example sets only the status lines of the US National CAD Standard, each value with the section of the standard that states it.
The presets are examples, and they are not complete. Each practice has a list of the values that wait for a control that Floorkit does not have yet, and a list of the values that no control can carry. Do not read a preset as the whole convention of a practice.

Use a preset

  1. Copy the paper styles into paperStyles of the paper document. Each key is a style id.
  2. Give each viewport the styleId for the kind of view it shows (see the table of the practice).
  3. Merge the view settings into each saved view of that kind. The keys site and loft-plan are not kinds of saved view: site is for a plan view with no storeyId (merge plan first, then site), and loft-plan is for the plan of the storey under the roof (merge it in place of plan). The words of hideForUsages must match the room usage values of your model.
  4. Set the viewport fields of the sheet settings on each viewport.
  5. Put the document style of the preset (typography and viewTitle) in the styleOverride of the paper document. A view title takes the style of the sheet, not the style of its viewport, so the font and the form of the titles come from the document.
  6. Set the sheet symbols of the preset on the viewport, the north arrow and the scale bar of each view of that kind.
  7. Set the model defaults of the preset on the building model. Each key is an element list of a storey, such as stairs, and each field goes on every element of that list, in every storey, where the element does not set it.
A viewport of a proposed ground-floor plan in the Epsom preset:
viewport.json
A style extends iso-128, so it says only what it changes. See Paper styles for each field. Colours are sampled from the real drawings: the mean colour of the largest colour cluster in a rectangle of the drawing, with each channel put in bins of 16. Lengths are measured in pixels on the same drawing, changed to model millimetres with a dimension of the drawing, and then to paper millimetres at 1:100.

Epsom practice

epsom-paper-styles.json
View settings, merged into each saved view of that kind:
epsom-view-settings.json
Viewport fields of the sheet settings:
epsom-sheet-settings.json
The style of the paper document, step 5. The view titles have no rule, are bold, and word the scale Scale 1:100:
epsom-document-style.json
The sheet symbols, by view kind. border goes on the viewport of that view, northArrow on its north arrow annotation and scaleBar on its scale bar annotation:
epsom-sheet-symbols.json
The model defaults, step 7. A stair rises at most 220 mm and is built of 25 mm boards:
epsom-model-defaults.json
Where the values come from: each value is measured on the planning application drawings of the Epsom house, on the sheet and the element named in the table. The largest stair riser comes from the building regulations. Waits for a control:
  • The area of the ground floor bathroom. The real plan prints (1.5m²) with no ceiling height; with outranksCeilingHeight our label still finds no clear place for the name and area among the fittings and the door swing, so it prints the name alone.
  • The area of a room by room, not by usage: the outer utility passage and the first floor store print no area, but the new utility and the storage area do, so the preset leaves utility and store out of hideForUsages. The ceiling height also shows on some rooms only (not on the garage, the bathrooms, the study or the outer utility).
  • FLO-548: door posts and the bifold drawn as a screen; the window sill with a curved front.
  • FLO-549: dormer cheeks and roof in the roof plan.
  • FLO-550: the many narrow slats of the sectional garage door in the existing front elevation; the part names of the windows of a dormer, so that the frame band, the sill and the frame weight reach the dormer window of the rear elevation.
  • FLO-551: room outlines in sections; the construction below the ground line left out; the knee walls of the loft drawn as cut.
  • FLO-552: the map fills of the location plan (beige buildings, green plots, grey roads).
  • FLO-558: the view title on the sheet and the site statistics (the controls of FLO-545 and FLO-552 depend on it).
Cannot say yet:
  • Room names in a medium weight. fontWeight is normal or bold, so the preset uses bold.
  • Areas to the nearest 0.5 m². The real labels step by 0.5 m² ((16m²)); trimZeros and decimals cannot round to 0.5, so the preset prints the model area to one decimal, (15.7m²) for that room.
  • How deep a section sees past its cut. The real section shows parts beyond the cut, so settings.context: 'cut-only' is wrong, and the depth is a choice for each view, not a convention.
  • The “Boundary Line” label reading top down. siteBoundaryLabel writes it bottom up.
  • The oriel corbel profile: this is element geometry, not a drawing convention.
  • The grey fill of the garage door, #d7d7d7 (sampled on the sheet “Existing and proposed front and rear elevations”, existing front elevation: the garage door). DOOR.parts.door-panel fills the panels of every panelled door, and the real front door has white panels, so the preset sets no panel fill.
  • The whole flight of the stair on the proposed first floor plan. The real plan draws the treads from the store wall down the stair well. aboveCut: 'continuous' draws only the part of the flight above the stair’s own cut, inside its stair well.

Bexley practice

The Bexley set has no site plan or location plan, so the preset has no site style.
bexley-paper-styles.json
The drawings of the existing building have no phase, so the material hatches would draw on them too. The real existing drawings show no hatch. Put this overlay in styleOverride of each viewport of an existing drawing:
bexley-existing-set-overlay.json
View settings, merged into each saved view of that kind:
bexley-view-settings.json
loft-plan is for the plan of the storey under the roof, in place of plan. It draws the roof seen from the loft: the roofs below the cut and the roof lines above it. The bexley-loft-plan style draws them as solid thin lines. The other plans draw no roof. The loft plan also draws a dashed line where the underside of the roof is 1.5 m above the loft floor, as the real proposed loft plan does. side-elevation is for the two side elevations along the party walls, in place of elevation. The real side elevations draw no sill. In the real sections the ground runs under the front and back steps to the outer wall faces, and about 0.65 m past each wall where no step stands. Viewport fields of the sheet settings:
bexley-sheet-settings.json
The style of the paper document, step 5. The view titles have no rule:
bexley-document-style.json
The existing set prints the room names only. Merge this into each plan view of the existing set, after the plan settings:
bexley-existing-set-plan.json
The model defaults, step 7. A stair rises at most 220 mm:
bexley-model-defaults.json
Where the values come from: each value is measured on the planning application drawings of the Bexley house, on the sheet and the element named in the table. The largest stair riser comes from the building regulations. Waits for a control:
  • Room names and notes in capitals with the units in lower case (16.3m2). typography.textTransform sets the case of every text of a style, units too, so the preset does not set it.
  • The view title at the top right of sections and elevations only. viewTitle.position is one value for the whole sheet, so the preset does not set it.
  • FLO-550: the part names of the windows of a dormer, so that sashOutlines, the sill and the glazing fill reach the dormer windows of the rear elevation.
  • FLO-558: the view title on the sheet.
Cannot say yet:
  • The glazing fill on a proposed elevation. The fill takes the phase of the window or the door, so it reaches only a view with phaseFilter: 'proposed' or 'existing'. A proposed elevation uses phaseFilter: 'complete', which draws no phase, and 'proposed' also draws the demolished elements. So the preset keeps the fills but sets no phaseFilter.
  • The break line of the stair. The real plan draws one zig-zag break line. No breakLine value draws a zig-zag, so the preset keeps double: two straight lines a tenth of the stair width apart.
  • The “Boundary” label level at the top end of each boundary line. siteBoundaryLabel writes it along the line.
  • The CAD lettering face. The real drawings use a CAD font that has no name we can give, so the preset sets no font.
  • A site plan and a location plan: the Bexley set has none.
  • The roof plan: the Bexley set has no roof plan crop, so only the slope symbols are set.
  • The roof of the rear extension on the ground plan. The real plan draws no line there. Floorkit draws that roof on the ground plan as cut, not above the cut, as a dashed outline, so linesAboveCut does not remove it.
  • The facet ticks of the bay bands in elevation. The preset hides the crease lines of windows only, so the bay window facets go and the eaves fascia keeps its second line. The bay bands and the bay base are floors, and their creases still draw a short vertical at each facet, which the real drawings do not show. A setting per element type cannot hide the creases of a bay band and keep the creases of the other floors.

US National CAD Standard: status lines

This example sets only the values that the published pages of the United States National CAD Standard (NCS) state. It is not a US convention: the NCS is a sold standard, and of the pages that are free to read, only two status lines and the table of line widths fit a control of Floorkit.
us-paper-styles.json
The status lines draw only in a view with phaseFilter: 'proposed' or 'existing', the same as every phase style. A phase weight applies to every line of that phase, so the cut lines of an existing wall also print at 0.25 mm; its hidden edges stay one rung lighter. Where the values come from: NCS Version 6 (2014), the sample pages that the National Institute of Building Sciences publishes on the NCS website, read on 13 November 2026. What the preset does not set, and why:
  • The line widths of Plotting Guidelines section 2.0 (0.13, 0.18, 0.25, 0.35, 0.50, 0.70, 1.00, 1.40 and 2.00 mm) are already the ladder of iso-128, so the preset does not repeat them.
  • The existing line is continuous (“use CONTINUOUS LT”). An existing element already draws continuous lines, so the preset sets no dash; a dash of "none" would also remove the dashes of its hidden edges.
  • The status field codes of the AIA CAD Layer Guidelines, section 1.7 (A, D, E, F, M, N, T, X and 1 to 9, sample), name CAD layers. They give no line, colour or fill, and a paper style has no layer names.
  • Not stated by the source: the new work line; the ink, fill and hatch of each phase; the weight of each class, role and depth band (UDS Module 4, Drafting Conventions, is on sale only); the typography; every view setting; every sheet setting.
  • NCS Version 7 is the current version. Its sample pages were not found on the NCS website on 13 November 2026, so the values are not checked against Version 7.

Next

Compose a sheet

Put the views on a sheet with viewports and titles.

Paper styles API

See each field of a paper style.
Last modified on November 16, 2026